 |
AUBE '99 Conference Proceedings:
For EUSAS members only: Download AUBE '99 (PDF, 26 MB).
11. Internationale Konferenz über Automatische Brandentdeckung,
16.-18. März 1999 in Duisburg, Germany
Contents AUBE ’99
|
|
Page
|
Luck, H., Sievert, U. |
Does an Over-All Modelling Make Any Sense in Automatic Fire Detection? |
1 |
Bukowski, R.W.,
Reneke, P.A. |
New Approaches to the Interpretation of Signals from Fire Sensors |
11 |
Björkman, J., Baroudi, D.,
Kokkala, M., Latva, R.
Tuomisaari, M. |
Determination of Characteristic Parameters of Point-type Smoke Detectors |
22 |
Cleary, Th., Grosshandler, W.,
Chernovsky, A. |
Smoke Detector Response to Nuisance Aerosols |
32 |
Ishii, H., Kawamura, K., Ono, T., Momma, E.,
Kawai, M. |
Fibre-optic Sensing Measurement and Thermofluid Dynamical Analysis of Temperature Distribution in Utility Tunnels |
42 |
Kaiser, Th., Wang, D.,
Eikermann, L. |
Ortsbestimmung von Bränden mit Temperatursensorgruppen |
52 |
Nebiker, P.W., Pleisch, R.E. |
Photoacoustic Gas Detection for Fire Warning |
67 |
Schwarz, A.,
Eberheim, A., Kohl, D.,
Menge, F.J., Petig, H. |
Detection of Glow Spots and Overheated Break at a Lignite Conveyor System by a Gas Sensor Array |
77 |
Hensel, A. |
Multigassensoren auf optoelektronischer Basis und deren Einsatz für die Branderkennung |
92 |
Hahne, J., Engel, R.,
Pehlke, J. |
Ergebnisse eigener Untersuchung zur Brandbekämpfung an Bord von Seeschiffen unter Einsatz der Gasanalyse der Raumluft und der Fuzzy-Technik |
105 |
Zhang, X., Jian, L. |
IR Beam Gas Detection System |
114 |
Linden, O., Hölemann, H. |
Versuche zur Eignung von Gassensoren für die Brandmeldetechnik |
122 |
Holländer, W., Lödding, H.,
Dunkhorst, W. |
A Cascade Impactor with Electrical Detection Optimized for Field Use |
140 |
Tamm, E., Mirme, A.,
Sievert, U., Franken, D. |
Aerosol Particle Concentration and Size Distribution Measurements of Test-Fires as Background for Fire-Detector Modelling |
150 |
Gockel, F. |
Messung der elektrischen Ladung bei Testbränden |
160 |
Thuillard, M. |
A New Flame Detector Using the Latest Research on Flames and Fuzzy-Wavelet Algorithms |
170 |
Kozeki, D. |
Observation of Early Stage Fires by a Multi Spectrum Camera |
180 |
Kuhn-Matysiak, U. |
Erkennung von Aerosolen nach dem Extinktionsprinzip auf kurzen Meßdistanzen |
187 |
Churches, D.K., da-Silva, E.,
Holifield , D. |
Smoke Detection by Ultrasound-Determination of Particle Mass Concentration |
198 |
Wang, H., Wang, S., Dou, Z.,
Yang, Z. |
The Application of Wavelet Neural Network in Fire Detection |
208 |
Bellavia , N.J. |
Detection in Difficult Environments |
213 |
Krippendorf, T. |
Streulichtmelder mit mehreren Streuwinkeln |
219 |
Keding, H.-J., Heckt, L.,
Borcherding, G. |
SamDetect - Ein intelligenter Brand- und Gefahrstoffsensor |
226 |
Gottuk, D.T.,
Peatross, M.J.,
Roby, R.L., Beyler, C.L. |
Advanced Fire Detection Using Multi-signature Alarm Algorithms |
237 |
Conforti, F. |
Multi-Sensor, Multi-Criteria Detection are better |
247 |
Oppelt, U. |
Auswerteverfahren für die Multisensorik für eine sicherere Meldungsentscheidung bei Bandereignissen |
251 |
Wang, L., Zhu, C., Wang, J. |
A New Type of Intelligent Point Photoelectric Smoke- Heat Combined Fire Detector |
262 |
Müller, H.-Ch. |
Die Auswertung der Brandkenngröße Kohlenmonoxidkonzentration in Multisensor-Detektorsystemen |
272 |
Petig, H., Kelleter, J.
Schwarz, A., Eberheim, A.,
Uwira, V., Kohl, D. |
History of Development Steps in Gas Sensor Fire Detection in RWE Powerplants for Lignite and Waste Combustion |
284 |
Lenkeit, K., Golloch, G.,
Schumann, A. |
Tests Regarding the Suitability and Use of Ion Mobility Spectrometers for Early Detection of Chemical Degradation Products |
295 |
Notz, R. |
New Fire Detection Concepts with Fiber Optics Technology |
303 |
Höppner, K. |
Anlagen zur automatischen Ortung und Sichtbarmachung von Glutnestern in Müllbunkern |
313 |
Nan, C. |
Fire Parameter Detecting Arithmetic and Its Application Researches |
323 |
Siebel, R. |
Ein LOW-COST Flammenmelder mit guten Alarm- und Falschalarmeigenschaften |
330 |
Vockenhuber, P., Kienle, Th. |
Temperature Sensor Cable SecuriSens TSC 511 |
337 |
Wang, S., Dou, Z. |
Biased Filter Algorithm of Multiple Sensor Signals for Automatic Fire Detection |
347 |
Ramachandran, S. |
Reliability Analysis Techniques to Improve Discrimination between Fire and False Alarms |
354 |
Willms, H.I. |
Volumetric Measurement Methods of Fire Phenomena |
365 |
Letts, J.B. |
False Fire Alarms
A Partnership Approach for Resolving Problems |
373 |
Mirme, A., Tamm, E.,
Sievert, U. |
Performance of an Optical and an Ionisation Smoke Detector Compared to a Wide Range Aerosol Spectrometer |
380 |
Jensen, G., Lønvik, T.,
Heskestad, A.W. |
Application Specific Sensitivity: A Simple Engineering Model to Predict Response of Installed Smoke Detectors |
392 |
Friedl, W.J. |
Praktische Erfahrungen eines Brandschutz-Ingenieurs mit der Installation von Brandmeldeanlagen in der Industrie |
403 |
Sieplmeyer-Kierdorf, L. |
Brandmeldeanlagen aus der Erfahrung eines Brandschutz-Fachingenieurs bzw. der industriellen Feuerversicherung |
413 |
Dubois, P. |
Comptabilit é électromagnétique des installations de détection incendie |
425 |
Tamura, H. |
Immunity Performance of Fire Detectors against Radiated Electromagnetic Field |
437 |
Anderson, D.D. |
Laser Spot Detector Technology for Early Warning of Smoke |
447 |
Penney, S. |
Development of a New Fire Detection Technology |
458 |
Hölemann, H., Kubon, Ch., Lais, Ch., Larisch, M. |
Untersuchungen über Einsatz mobiler Brandmeldeanlagen |
468 |
Romeike, R. |
Täuschungsalarme von Brandmeldeanlagen durch Löschgasübertragung in Nachbarbereiche |
478 |
Christensen, E. |
Development and Testing of a Self-Contained Smoke Alarm for Trucks |
487 |
Hess, E. |
Untersuchungen über Veränderungen der Ansprechschwelle von Rauchmeldern in der Praxis |
499 |
Schreyer, K. |
Professionelle Funk-Gefahrenmeldeanlage im SRD-Band |
503 |
Husser, J. |
Achieving Optimum Reliability in Wireless Alarm Systems |
513 |
Steck, K. |
Transmission of Fire Alarm in ISDN |
523 |
Pinney, A.A. |
The Construction Products Directive and the Background to and Principles of Harmonisation |
533 |
Appleby, D.,
Scheidweiler, A.,
Langeveld, B. van |
The Interpretation of European Standards for Control and Indicating Equipment (EN54-2) and Power Supplies (EN54-4) |
543 |
Sans, J.G. |
Standardisation in Fire Detection and Fire Alarm System |
551 |
Reynolds, C.F. |
Euralarm - Its Role in Standard, Testing and Certification |
559 |
Alrøe, H. |
Environmental Test Requirements for Fire Alarm Equipment Used for Marine Application Compared to Test Requirements for Industrial Applications |
567 |
Spearpoint, M.J.,
Smithies, J.N. |
Practical Comparison of Domestic Smoke Alarm Sensitivity Standards |
576 |
Li, J. |
Standards and Certification for Fire Detection and Alarm Equipment in P.R.China |
588 |
Cremer, A.S. |
Melder für den privaten Haushalt |
595 |
Meier, O. |
Lautsprecher-Alarm-Systeme; Stand der Technik und Entwicklungs-Konzepte |
605 |
Kaufmann, F. |
Anwendungen des BACnet Standards in der Gefahrenmeldetechnik |
613 |
Beilicke, G. |
Automatische Brandschutztechnik und ihr Zusammenwirken mit der Hausleittechnik |
623 |
Grinewitschus, V.,
Scherer, K. |
Eine informationstechnische Multifunktionsplattform für heterogene Haussysteme |
633 |
Kristen, W. |
Einsatz des Europäischen Installationsbusses in der Sicherungstechnik |
642 |
Letts, J.B. |
Integrated Systems - Proposals for Addressing Fire Detection and Alarm System Integrity Issues as the Level of Integration Increases |
654 |
|